  "title": "Florida OSTDS Sizing Reference Dataset",
  "version": "2026.2",
  "compiled_by": "Tallahassee Septic Repair Research",
  "last_verified": "2026-07-23",
  "method": "Derived by joining Fla. Admin. Code R. 62-6.008 Table I (estimated sewage flow), Table I footnote 4 (greatest-flow rule), Table II (minimum effective septic-tank and pump-tank capacity), Table III (soil loading rates), and R. 62-6.013(2) (freeboard and chamber minimums). All derived values use exact integer or rational arithmetic and are planning references, not permit determinations. The chamber fields are standalone minimums; the combined first and second chambers must also equal or exceed the total required effective capacity.",
  "primary_sources": [
    {
      "id": "R1",
      "citation": "Fla. Admin. Code R. 62-6.008, System Size Determinations (effective July 16, 2013)",
      "url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "checked": "2026-07-23"
    },
    {
      "id": "R2",
      "citation": "Fla. Admin. Code R. 62-6.013, Construction Materials and Standards for Tanks (current version effective June 8, 2026)",
      "url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.013",
      "checked": "2026-07-23"
    },
    {
      "id": "R3",
      "citation": "Fla. Admin. Code R. 62-6.002, Definitions (current version effective July 9, 2025)",
      "url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.002",
      "checked": "2026-07-23"
    },
    {
      "id": "R4",
      "citation": "Fla. Admin. Code R. 62-6.001, General (current version effective July 9, 2025)",
      "url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.001",
      "checked": "2026-07-23"
    },
    {
      "id": "S1",
      "citation": "Section 381.0065, Florida Statutes (2025), as amended by Chapter 2026-62, Laws of Florida",
      "url": "https://laws.flrules.org/2026/62",
      "checked": "2026-07-23"
    },
    {
      "id": "D1",
      "citation": "Florida DEP, Onsite Sewage FAQ – Permitting (page last modified January 20, 2026)",
      "url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "checked": "2026-07-23"
    },
    {
      "id": "D2",
      "citation": "Florida DEP, February 2026 Enhanced Nutrient-Reducing Requirements for OSTDS",
      "url": "https://floridadep.gov/sites/default/files/2026.02.03_BMAP%20tables.pdf",
      "checked": "2026-07-23"
    }
  ],
  "constants_from_rule": {
    "minimum_effective_capacity_floor_gal": 900,
    "freeboard_minimum_fraction_of_effective_capacity": 0.15,
    "first_chamber_minimum_fraction": "2/3",
    "second_chamber_minimum_fraction": "1/5",
    "minimum_liquid_depth_inches_septic_tank": 40,
    "liquid_depth_not_counted_above_inches": 84,
    "drainfield_minimum_design_flow_gpd": 200,
    "additional_bedroom_or_750_sqft_increment_gpd": 60,
    "footnote_4_rule": "max(bedroom criterion, building-area criterion)"
  },
  "tank_sizing_matrix": [
    {
      "bedrooms": 1,
      "building_area_band": "750 sq ft or less",
      "flow_from_bedrooms_gpd": 100,
      "flow_from_building_area_gpd": 100,
      "governing_criterion": "tie (identical)",
      "design_sewage_flow_gpd": 100,
      "min_septic_tank_effective_capacity_gal": 900,
      "min_residential_pump_tank_total_capacity_gal": 150,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1035.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 600,
      "second_chamber_standalone_min_effective_gal": 180,
      "combined_first_second_min_effective_capacity_gal": 900
    },
    {
      "bedrooms": 1,
      "building_area_band": "751-1,200 sq ft",
      "flow_from_bedrooms_gpd": 100,
      "flow_from_building_area_gpd": 200,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 200,
      "min_septic_tank_effective_capacity_gal": 900,
      "min_residential_pump_tank_total_capacity_gal": 150,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1035.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 600,
      "second_chamber_standalone_min_effective_gal": 180,
      "combined_first_second_min_effective_capacity_gal": 900
    },
    {
      "bedrooms": 1,
      "building_area_band": "1,201-2,250 sq ft",
      "flow_from_bedrooms_gpd": 100,
      "flow_from_building_area_gpd": 300,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 300,
      "min_septic_tank_effective_capacity_gal": 900,
      "min_residential_pump_tank_total_capacity_gal": 225,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1035.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 600,
      "second_chamber_standalone_min_effective_gal": 180,
      "combined_first_second_min_effective_capacity_gal": 900
    },
    {
      "bedrooms": 1,
      "building_area_band": "2,251-3,300 sq ft",
      "flow_from_bedrooms_gpd": 100,
      "flow_from_building_area_gpd": 400,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 400,
      "min_septic_tank_effective_capacity_gal": 1050,
      "min_residential_pump_tank_total_capacity_gal": 300,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1207.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 700,
      "second_chamber_standalone_min_effective_gal": 210,
      "combined_first_second_min_effective_capacity_gal": 1050
    },
    {
      "bedrooms": 1,
      "building_area_band": "3,301-4,050 sq ft",
      "flow_from_bedrooms_gpd": 100,
      "flow_from_building_area_gpd": 460,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 460,
      "min_septic_tank_effective_capacity_gal": 1200,
      "min_residential_pump_tank_total_capacity_gal": 375,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1380.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 800,
      "second_chamber_standalone_min_effective_gal": 240,
      "combined_first_second_min_effective_capacity_gal": 1200
    },
    {
      "bedrooms": 1,
      "building_area_band": "4,051-4,800 sq ft",
      "flow_from_bedrooms_gpd": 100,
      "flow_from_building_area_gpd": 520,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 520,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 1,
      "building_area_band": "4,801-5,550 sq ft",
      "flow_from_bedrooms_gpd": 100,
      "flow_from_building_area_gpd": 580,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 580,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 1,
      "building_area_band": "5,551-6,300 sq ft",
      "flow_from_bedrooms_gpd": 100,
      "flow_from_building_area_gpd": 640,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 1,
      "building_area_band": "6,301-7,050 sq ft",
      "flow_from_bedrooms_gpd": 100,
      "flow_from_building_area_gpd": 700,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 1,
      "building_area_band": "7,051-7,800 sq ft",
      "flow_from_bedrooms_gpd": 100,
      "flow_from_building_area_gpd": 760,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 2,
      "building_area_band": "750 sq ft or less",
      "flow_from_bedrooms_gpd": 200,
      "flow_from_building_area_gpd": 100,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 200,
      "min_septic_tank_effective_capacity_gal": 900,
      "min_residential_pump_tank_total_capacity_gal": 150,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1035.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 600,
      "second_chamber_standalone_min_effective_gal": 180,
      "combined_first_second_min_effective_capacity_gal": 900
    },
    {
      "bedrooms": 2,
      "building_area_band": "751-1,200 sq ft",
      "flow_from_bedrooms_gpd": 200,
      "flow_from_building_area_gpd": 200,
      "governing_criterion": "tie (identical)",
      "design_sewage_flow_gpd": 200,
      "min_septic_tank_effective_capacity_gal": 900,
      "min_residential_pump_tank_total_capacity_gal": 150,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1035.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 600,
      "second_chamber_standalone_min_effective_gal": 180,
      "combined_first_second_min_effective_capacity_gal": 900
    },
    {
      "bedrooms": 2,
      "building_area_band": "1,201-2,250 sq ft",
      "flow_from_bedrooms_gpd": 200,
      "flow_from_building_area_gpd": 300,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 300,
      "min_septic_tank_effective_capacity_gal": 900,
      "min_residential_pump_tank_total_capacity_gal": 225,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1035.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 600,
      "second_chamber_standalone_min_effective_gal": 180,
      "combined_first_second_min_effective_capacity_gal": 900
    },
    {
      "bedrooms": 2,
      "building_area_band": "2,251-3,300 sq ft",
      "flow_from_bedrooms_gpd": 200,
      "flow_from_building_area_gpd": 400,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 400,
      "min_septic_tank_effective_capacity_gal": 1050,
      "min_residential_pump_tank_total_capacity_gal": 300,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1207.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 700,
      "second_chamber_standalone_min_effective_gal": 210,
      "combined_first_second_min_effective_capacity_gal": 1050
    },
    {
      "bedrooms": 2,
      "building_area_band": "3,301-4,050 sq ft",
      "flow_from_bedrooms_gpd": 200,
      "flow_from_building_area_gpd": 460,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 460,
      "min_septic_tank_effective_capacity_gal": 1200,
      "min_residential_pump_tank_total_capacity_gal": 375,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1380.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 800,
      "second_chamber_standalone_min_effective_gal": 240,
      "combined_first_second_min_effective_capacity_gal": 1200
    },
    {
      "bedrooms": 2,
      "building_area_band": "4,051-4,800 sq ft",
      "flow_from_bedrooms_gpd": 200,
      "flow_from_building_area_gpd": 520,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 520,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 2,
      "building_area_band": "4,801-5,550 sq ft",
      "flow_from_bedrooms_gpd": 200,
      "flow_from_building_area_gpd": 580,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 580,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 2,
      "building_area_band": "5,551-6,300 sq ft",
      "flow_from_bedrooms_gpd": 200,
      "flow_from_building_area_gpd": 640,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 2,
      "building_area_band": "6,301-7,050 sq ft",
      "flow_from_bedrooms_gpd": 200,
      "flow_from_building_area_gpd": 700,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 2,
      "building_area_band": "7,051-7,800 sq ft",
      "flow_from_bedrooms_gpd": 200,
      "flow_from_building_area_gpd": 760,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 3,
      "building_area_band": "750 sq ft or less",
      "flow_from_bedrooms_gpd": 300,
      "flow_from_building_area_gpd": 100,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 300,
      "min_septic_tank_effective_capacity_gal": 900,
      "min_residential_pump_tank_total_capacity_gal": 225,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1035.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 600,
      "second_chamber_standalone_min_effective_gal": 180,
      "combined_first_second_min_effective_capacity_gal": 900
    },
    {
      "bedrooms": 3,
      "building_area_band": "751-1,200 sq ft",
      "flow_from_bedrooms_gpd": 300,
      "flow_from_building_area_gpd": 200,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 300,
      "min_septic_tank_effective_capacity_gal": 900,
      "min_residential_pump_tank_total_capacity_gal": 225,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1035.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 600,
      "second_chamber_standalone_min_effective_gal": 180,
      "combined_first_second_min_effective_capacity_gal": 900
    },
    {
      "bedrooms": 3,
      "building_area_band": "1,201-2,250 sq ft",
      "flow_from_bedrooms_gpd": 300,
      "flow_from_building_area_gpd": 300,
      "governing_criterion": "tie (identical)",
      "design_sewage_flow_gpd": 300,
      "min_septic_tank_effective_capacity_gal": 900,
      "min_residential_pump_tank_total_capacity_gal": 225,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1035.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 600,
      "second_chamber_standalone_min_effective_gal": 180,
      "combined_first_second_min_effective_capacity_gal": 900
    },
    {
      "bedrooms": 3,
      "building_area_band": "2,251-3,300 sq ft",
      "flow_from_bedrooms_gpd": 300,
      "flow_from_building_area_gpd": 400,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 400,
      "min_septic_tank_effective_capacity_gal": 1050,
      "min_residential_pump_tank_total_capacity_gal": 300,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1207.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 700,
      "second_chamber_standalone_min_effective_gal": 210,
      "combined_first_second_min_effective_capacity_gal": 1050
    },
    {
      "bedrooms": 3,
      "building_area_band": "3,301-4,050 sq ft",
      "flow_from_bedrooms_gpd": 300,
      "flow_from_building_area_gpd": 460,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 460,
      "min_septic_tank_effective_capacity_gal": 1200,
      "min_residential_pump_tank_total_capacity_gal": 375,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1380.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 800,
      "second_chamber_standalone_min_effective_gal": 240,
      "combined_first_second_min_effective_capacity_gal": 1200
    },
    {
      "bedrooms": 3,
      "building_area_band": "4,051-4,800 sq ft",
      "flow_from_bedrooms_gpd": 300,
      "flow_from_building_area_gpd": 520,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 520,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 3,
      "building_area_band": "4,801-5,550 sq ft",
      "flow_from_bedrooms_gpd": 300,
      "flow_from_building_area_gpd": 580,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 580,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 3,
      "building_area_band": "5,551-6,300 sq ft",
      "flow_from_bedrooms_gpd": 300,
      "flow_from_building_area_gpd": 640,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 3,
      "building_area_band": "6,301-7,050 sq ft",
      "flow_from_bedrooms_gpd": 300,
      "flow_from_building_area_gpd": 700,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 3,
      "building_area_band": "7,051-7,800 sq ft",
      "flow_from_bedrooms_gpd": 300,
      "flow_from_building_area_gpd": 760,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 4,
      "building_area_band": "750 sq ft or less",
      "flow_from_bedrooms_gpd": 400,
      "flow_from_building_area_gpd": 100,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 400,
      "min_septic_tank_effective_capacity_gal": 1050,
      "min_residential_pump_tank_total_capacity_gal": 300,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1207.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 700,
      "second_chamber_standalone_min_effective_gal": 210,
      "combined_first_second_min_effective_capacity_gal": 1050
    },
    {
      "bedrooms": 4,
      "building_area_band": "751-1,200 sq ft",
      "flow_from_bedrooms_gpd": 400,
      "flow_from_building_area_gpd": 200,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 400,
      "min_septic_tank_effective_capacity_gal": 1050,
      "min_residential_pump_tank_total_capacity_gal": 300,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1207.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 700,
      "second_chamber_standalone_min_effective_gal": 210,
      "combined_first_second_min_effective_capacity_gal": 1050
    },
    {
      "bedrooms": 4,
      "building_area_band": "1,201-2,250 sq ft",
      "flow_from_bedrooms_gpd": 400,
      "flow_from_building_area_gpd": 300,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 400,
      "min_septic_tank_effective_capacity_gal": 1050,
      "min_residential_pump_tank_total_capacity_gal": 300,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1207.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 700,
      "second_chamber_standalone_min_effective_gal": 210,
      "combined_first_second_min_effective_capacity_gal": 1050
    },
    {
      "bedrooms": 4,
      "building_area_band": "2,251-3,300 sq ft",
      "flow_from_bedrooms_gpd": 400,
      "flow_from_building_area_gpd": 400,
      "governing_criterion": "tie (identical)",
      "design_sewage_flow_gpd": 400,
      "min_septic_tank_effective_capacity_gal": 1050,
      "min_residential_pump_tank_total_capacity_gal": 300,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1207.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 700,
      "second_chamber_standalone_min_effective_gal": 210,
      "combined_first_second_min_effective_capacity_gal": 1050
    },
    {
      "bedrooms": 4,
      "building_area_band": "3,301-4,050 sq ft",
      "flow_from_bedrooms_gpd": 400,
      "flow_from_building_area_gpd": 460,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 460,
      "min_septic_tank_effective_capacity_gal": 1200,
      "min_residential_pump_tank_total_capacity_gal": 375,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1380.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 800,
      "second_chamber_standalone_min_effective_gal": 240,
      "combined_first_second_min_effective_capacity_gal": 1200
    },
    {
      "bedrooms": 4,
      "building_area_band": "4,051-4,800 sq ft",
      "flow_from_bedrooms_gpd": 400,
      "flow_from_building_area_gpd": 520,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 520,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 4,
      "building_area_band": "4,801-5,550 sq ft",
      "flow_from_bedrooms_gpd": 400,
      "flow_from_building_area_gpd": 580,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 580,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 4,
      "building_area_band": "5,551-6,300 sq ft",
      "flow_from_bedrooms_gpd": 400,
      "flow_from_building_area_gpd": 640,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 4,
      "building_area_band": "6,301-7,050 sq ft",
      "flow_from_bedrooms_gpd": 400,
      "flow_from_building_area_gpd": 700,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 4,
      "building_area_band": "7,051-7,800 sq ft",
      "flow_from_bedrooms_gpd": 400,
      "flow_from_building_area_gpd": 760,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 5,
      "building_area_band": "750 sq ft or less",
      "flow_from_bedrooms_gpd": 460,
      "flow_from_building_area_gpd": 100,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 460,
      "min_septic_tank_effective_capacity_gal": 1200,
      "min_residential_pump_tank_total_capacity_gal": 375,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1380.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 800,
      "second_chamber_standalone_min_effective_gal": 240,
      "combined_first_second_min_effective_capacity_gal": 1200
    },
    {
      "bedrooms": 5,
      "building_area_band": "751-1,200 sq ft",
      "flow_from_bedrooms_gpd": 460,
      "flow_from_building_area_gpd": 200,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 460,
      "min_septic_tank_effective_capacity_gal": 1200,
      "min_residential_pump_tank_total_capacity_gal": 375,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1380.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 800,
      "second_chamber_standalone_min_effective_gal": 240,
      "combined_first_second_min_effective_capacity_gal": 1200
    },
    {
      "bedrooms": 5,
      "building_area_band": "1,201-2,250 sq ft",
      "flow_from_bedrooms_gpd": 460,
      "flow_from_building_area_gpd": 300,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 460,
      "min_septic_tank_effective_capacity_gal": 1200,
      "min_residential_pump_tank_total_capacity_gal": 375,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1380.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 800,
      "second_chamber_standalone_min_effective_gal": 240,
      "combined_first_second_min_effective_capacity_gal": 1200
    },
    {
      "bedrooms": 5,
      "building_area_band": "2,251-3,300 sq ft",
      "flow_from_bedrooms_gpd": 460,
      "flow_from_building_area_gpd": 400,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 460,
      "min_septic_tank_effective_capacity_gal": 1200,
      "min_residential_pump_tank_total_capacity_gal": 375,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1380.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 800,
      "second_chamber_standalone_min_effective_gal": 240,
      "combined_first_second_min_effective_capacity_gal": 1200
    },
    {
      "bedrooms": 5,
      "building_area_band": "3,301-4,050 sq ft",
      "flow_from_bedrooms_gpd": 460,
      "flow_from_building_area_gpd": 460,
      "governing_criterion": "tie (identical)",
      "design_sewage_flow_gpd": 460,
      "min_septic_tank_effective_capacity_gal": 1200,
      "min_residential_pump_tank_total_capacity_gal": 375,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1380.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 800,
      "second_chamber_standalone_min_effective_gal": 240,
      "combined_first_second_min_effective_capacity_gal": 1200
    },
    {
      "bedrooms": 5,
      "building_area_band": "4,051-4,800 sq ft",
      "flow_from_bedrooms_gpd": 460,
      "flow_from_building_area_gpd": 520,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 520,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 5,
      "building_area_band": "4,801-5,550 sq ft",
      "flow_from_bedrooms_gpd": 460,
      "flow_from_building_area_gpd": 580,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 580,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 5,
      "building_area_band": "5,551-6,300 sq ft",
      "flow_from_bedrooms_gpd": 460,
      "flow_from_building_area_gpd": 640,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 5,
      "building_area_band": "6,301-7,050 sq ft",
      "flow_from_bedrooms_gpd": 460,
      "flow_from_building_area_gpd": 700,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 5,
      "building_area_band": "7,051-7,800 sq ft",
      "flow_from_bedrooms_gpd": 460,
      "flow_from_building_area_gpd": 760,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 6,
      "building_area_band": "750 sq ft or less",
      "flow_from_bedrooms_gpd": 520,
      "flow_from_building_area_gpd": 100,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 520,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 6,
      "building_area_band": "751-1,200 sq ft",
      "flow_from_bedrooms_gpd": 520,
      "flow_from_building_area_gpd": 200,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 520,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 6,
      "building_area_band": "1,201-2,250 sq ft",
      "flow_from_bedrooms_gpd": 520,
      "flow_from_building_area_gpd": 300,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 520,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 6,
      "building_area_band": "2,251-3,300 sq ft",
      "flow_from_bedrooms_gpd": 520,
      "flow_from_building_area_gpd": 400,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 520,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 6,
      "building_area_band": "3,301-4,050 sq ft",
      "flow_from_bedrooms_gpd": 520,
      "flow_from_building_area_gpd": 460,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 520,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 6,
      "building_area_band": "4,051-4,800 sq ft",
      "flow_from_bedrooms_gpd": 520,
      "flow_from_building_area_gpd": 520,
      "governing_criterion": "tie (identical)",
      "design_sewage_flow_gpd": 520,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 6,
      "building_area_band": "4,801-5,550 sq ft",
      "flow_from_bedrooms_gpd": 520,
      "flow_from_building_area_gpd": 580,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 580,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 6,
      "building_area_band": "5,551-6,300 sq ft",
      "flow_from_bedrooms_gpd": 520,
      "flow_from_building_area_gpd": 640,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 6,
      "building_area_band": "6,301-7,050 sq ft",
      "flow_from_bedrooms_gpd": 520,
      "flow_from_building_area_gpd": 700,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 6,
      "building_area_band": "7,051-7,800 sq ft",
      "flow_from_bedrooms_gpd": 520,
      "flow_from_building_area_gpd": 760,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 7,
      "building_area_band": "750 sq ft or less",
      "flow_from_bedrooms_gpd": 580,
      "flow_from_building_area_gpd": 100,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 580,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 7,
      "building_area_band": "751-1,200 sq ft",
      "flow_from_bedrooms_gpd": 580,
      "flow_from_building_area_gpd": 200,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 580,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 7,
      "building_area_band": "1,201-2,250 sq ft",
      "flow_from_bedrooms_gpd": 580,
      "flow_from_building_area_gpd": 300,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 580,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 7,
      "building_area_band": "2,251-3,300 sq ft",
      "flow_from_bedrooms_gpd": 580,
      "flow_from_building_area_gpd": 400,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 580,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 7,
      "building_area_band": "3,301-4,050 sq ft",
      "flow_from_bedrooms_gpd": 580,
      "flow_from_building_area_gpd": 460,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 580,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 7,
      "building_area_band": "4,051-4,800 sq ft",
      "flow_from_bedrooms_gpd": 580,
      "flow_from_building_area_gpd": 520,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 580,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 7,
      "building_area_band": "4,801-5,550 sq ft",
      "flow_from_bedrooms_gpd": 580,
      "flow_from_building_area_gpd": 580,
      "governing_criterion": "tie (identical)",
      "design_sewage_flow_gpd": 580,
      "min_septic_tank_effective_capacity_gal": 1350,
      "min_residential_pump_tank_total_capacity_gal": 450,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1552.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 900,
      "second_chamber_standalone_min_effective_gal": 270,
      "combined_first_second_min_effective_capacity_gal": 1350
    },
    {
      "bedrooms": 7,
      "building_area_band": "5,551-6,300 sq ft",
      "flow_from_bedrooms_gpd": 580,
      "flow_from_building_area_gpd": 640,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 7,
      "building_area_band": "6,301-7,050 sq ft",
      "flow_from_bedrooms_gpd": 580,
      "flow_from_building_area_gpd": 700,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 7,
      "building_area_band": "7,051-7,800 sq ft",
      "flow_from_bedrooms_gpd": 580,
      "flow_from_building_area_gpd": 760,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 8,
      "building_area_band": "750 sq ft or less",
      "flow_from_bedrooms_gpd": 640,
      "flow_from_building_area_gpd": 100,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 8,
      "building_area_band": "751-1,200 sq ft",
      "flow_from_bedrooms_gpd": 640,
      "flow_from_building_area_gpd": 200,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 8,
      "building_area_band": "1,201-2,250 sq ft",
      "flow_from_bedrooms_gpd": 640,
      "flow_from_building_area_gpd": 300,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 8,
      "building_area_band": "2,251-3,300 sq ft",
      "flow_from_bedrooms_gpd": 640,
      "flow_from_building_area_gpd": 400,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 8,
      "building_area_band": "3,301-4,050 sq ft",
      "flow_from_bedrooms_gpd": 640,
      "flow_from_building_area_gpd": 460,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 8,
      "building_area_band": "4,051-4,800 sq ft",
      "flow_from_bedrooms_gpd": 640,
      "flow_from_building_area_gpd": 520,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 8,
      "building_area_band": "4,801-5,550 sq ft",
      "flow_from_bedrooms_gpd": 640,
      "flow_from_building_area_gpd": 580,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 8,
      "building_area_band": "5,551-6,300 sq ft",
      "flow_from_bedrooms_gpd": 640,
      "flow_from_building_area_gpd": 640,
      "governing_criterion": "tie (identical)",
      "design_sewage_flow_gpd": 640,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 8,
      "building_area_band": "6,301-7,050 sq ft",
      "flow_from_bedrooms_gpd": 640,
      "flow_from_building_area_gpd": 700,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 8,
      "building_area_band": "7,051-7,800 sq ft",
      "flow_from_bedrooms_gpd": 640,
      "flow_from_building_area_gpd": 760,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 9,
      "building_area_band": "750 sq ft or less",
      "flow_from_bedrooms_gpd": 700,
      "flow_from_building_area_gpd": 100,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 9,
      "building_area_band": "751-1,200 sq ft",
      "flow_from_bedrooms_gpd": 700,
      "flow_from_building_area_gpd": 200,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 9,
      "building_area_band": "1,201-2,250 sq ft",
      "flow_from_bedrooms_gpd": 700,
      "flow_from_building_area_gpd": 300,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 9,
      "building_area_band": "2,251-3,300 sq ft",
      "flow_from_bedrooms_gpd": 700,
      "flow_from_building_area_gpd": 400,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 9,
      "building_area_band": "3,301-4,050 sq ft",
      "flow_from_bedrooms_gpd": 700,
      "flow_from_building_area_gpd": 460,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 9,
      "building_area_band": "4,051-4,800 sq ft",
      "flow_from_bedrooms_gpd": 700,
      "flow_from_building_area_gpd": 520,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 9,
      "building_area_band": "4,801-5,550 sq ft",
      "flow_from_bedrooms_gpd": 700,
      "flow_from_building_area_gpd": 580,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 9,
      "building_area_band": "5,551-6,300 sq ft",
      "flow_from_bedrooms_gpd": 700,
      "flow_from_building_area_gpd": 640,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 9,
      "building_area_band": "6,301-7,050 sq ft",
      "flow_from_bedrooms_gpd": 700,
      "flow_from_building_area_gpd": 700,
      "governing_criterion": "tie (identical)",
      "design_sewage_flow_gpd": 700,
      "min_septic_tank_effective_capacity_gal": 1500,
      "min_residential_pump_tank_total_capacity_gal": 525,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1725.0,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1000,
      "second_chamber_standalone_min_effective_gal": 300,
      "combined_first_second_min_effective_capacity_gal": 1500
    },
    {
      "bedrooms": 9,
      "building_area_band": "7,051-7,800 sq ft",
      "flow_from_bedrooms_gpd": 700,
      "flow_from_building_area_gpd": 760,
      "governing_criterion": "building area",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 10,
      "building_area_band": "750 sq ft or less",
      "flow_from_bedrooms_gpd": 760,
      "flow_from_building_area_gpd": 100,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 10,
      "building_area_band": "751-1,200 sq ft",
      "flow_from_bedrooms_gpd": 760,
      "flow_from_building_area_gpd": 200,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 10,
      "building_area_band": "1,201-2,250 sq ft",
      "flow_from_bedrooms_gpd": 760,
      "flow_from_building_area_gpd": 300,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 10,
      "building_area_band": "2,251-3,300 sq ft",
      "flow_from_bedrooms_gpd": 760,
      "flow_from_building_area_gpd": 400,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 10,
      "building_area_band": "3,301-4,050 sq ft",
      "flow_from_bedrooms_gpd": 760,
      "flow_from_building_area_gpd": 460,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 10,
      "building_area_band": "4,051-4,800 sq ft",
      "flow_from_bedrooms_gpd": 760,
      "flow_from_building_area_gpd": 520,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 10,
      "building_area_band": "4,801-5,550 sq ft",
      "flow_from_bedrooms_gpd": 760,
      "flow_from_building_area_gpd": 580,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 10,
      "building_area_band": "5,551-6,300 sq ft",
      "flow_from_bedrooms_gpd": 760,
      "flow_from_building_area_gpd": 640,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 10,
      "building_area_band": "6,301-7,050 sq ft",
      "flow_from_bedrooms_gpd": 760,
      "flow_from_building_area_gpd": 700,
      "governing_criterion": "bedroom count",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    },
    {
      "bedrooms": 10,
      "building_area_band": "7,051-7,800 sq ft",
      "flow_from_bedrooms_gpd": 760,
      "flow_from_building_area_gpd": 760,
      "governing_criterion": "tie (identical)",
      "design_sewage_flow_gpd": 760,
      "min_septic_tank_effective_capacity_gal": 1650,
      "min_residential_pump_tank_total_capacity_gal": 600,
      "min_gross_tank_volume_incl_15pct_freeboard_gal": 1897.5,
      "rule_citation": "Fla. Admin. Code R. 62-6.008 Tables I & II; R. 62-6.013(2)",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23",
      "first_chamber_standalone_min_effective_gal": 1100,
      "second_chamber_standalone_min_effective_gal": 330,
      "combined_first_second_min_effective_capacity_gal": 1650
    }
  ],
  "drainfield_absorption_area": [
    {
      "design_sewage_flow_gpd": 100,
      "flow_used_for_sizing_gpd": 200,
      "usda_soil_texture_classification": "Sand; Coarse Sand not associated with a seasonal water table of less than 48 inches; Loamy Coarse Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (<2 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 250,
      "min_bed_absorption_area_sqft": 334,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 100,
      "flow_used_for_sizing_gpd": 200,
      "usda_soil_texture_classification": "Loamy Sand; Sandy Loam; Coarse Sandy Loam; Fine Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (2-4 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 250,
      "min_bed_absorption_area_sqft": 334,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 100,
      "flow_used_for_sizing_gpd": 200,
      "usda_soil_texture_classification": "Loam; Fine Sandy Loam; Silt Loam; Very Fine Sand; Very Fine Sandy Loam; Loamy Fine Sand; Loamy Very Fine Sand; Sandy Clay Loam",
      "soil_texture_limitation_percolation_rate": "Moderately limited (5-10 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.65,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.35,
      "min_trench_absorption_area_sqft": 308,
      "min_bed_absorption_area_sqft": 572,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 100,
      "flow_used_for_sizing_gpd": 200,
      "usda_soil_texture_classification": "Clay Loam; Silty Clay Loam; Sandy Clay; Silty Clay; Silt",
      "soil_texture_limitation_percolation_rate": "Moderately limited (>15 but <=30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.35,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.2,
      "min_trench_absorption_area_sqft": 572,
      "min_bed_absorption_area_sqft": 1000,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 100,
      "flow_used_for_sizing_gpd": 200,
      "usda_soil_texture_classification": "Clay; Organic Soils; Hardpan; Bedrock",
      "soil_texture_limitation_percolation_rate": "Severely limited (>30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 100,
      "flow_used_for_sizing_gpd": 200,
      "usda_soil_texture_classification": "Coarse Sand with estimated wet season high water table within 48 inches of the bottom of the proposed drainfield; Gravel; Fractured Rock; Oolitic Limestone",
      "soil_texture_limitation_percolation_rate": "Severely limited (<1 min/inch and water table <4 ft below drainfield)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 200,
      "flow_used_for_sizing_gpd": 200,
      "usda_soil_texture_classification": "Sand; Coarse Sand not associated with a seasonal water table of less than 48 inches; Loamy Coarse Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (<2 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 250,
      "min_bed_absorption_area_sqft": 334,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 200,
      "flow_used_for_sizing_gpd": 200,
      "usda_soil_texture_classification": "Loamy Sand; Sandy Loam; Coarse Sandy Loam; Fine Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (2-4 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 250,
      "min_bed_absorption_area_sqft": 334,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 200,
      "flow_used_for_sizing_gpd": 200,
      "usda_soil_texture_classification": "Loam; Fine Sandy Loam; Silt Loam; Very Fine Sand; Very Fine Sandy Loam; Loamy Fine Sand; Loamy Very Fine Sand; Sandy Clay Loam",
      "soil_texture_limitation_percolation_rate": "Moderately limited (5-10 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.65,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.35,
      "min_trench_absorption_area_sqft": 308,
      "min_bed_absorption_area_sqft": 572,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 200,
      "flow_used_for_sizing_gpd": 200,
      "usda_soil_texture_classification": "Clay Loam; Silty Clay Loam; Sandy Clay; Silty Clay; Silt",
      "soil_texture_limitation_percolation_rate": "Moderately limited (>15 but <=30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.35,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.2,
      "min_trench_absorption_area_sqft": 572,
      "min_bed_absorption_area_sqft": 1000,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 200,
      "flow_used_for_sizing_gpd": 200,
      "usda_soil_texture_classification": "Clay; Organic Soils; Hardpan; Bedrock",
      "soil_texture_limitation_percolation_rate": "Severely limited (>30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 200,
      "flow_used_for_sizing_gpd": 200,
      "usda_soil_texture_classification": "Coarse Sand with estimated wet season high water table within 48 inches of the bottom of the proposed drainfield; Gravel; Fractured Rock; Oolitic Limestone",
      "soil_texture_limitation_percolation_rate": "Severely limited (<1 min/inch and water table <4 ft below drainfield)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 300,
      "flow_used_for_sizing_gpd": 300,
      "usda_soil_texture_classification": "Sand; Coarse Sand not associated with a seasonal water table of less than 48 inches; Loamy Coarse Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (<2 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 375,
      "min_bed_absorption_area_sqft": 500,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 300,
      "flow_used_for_sizing_gpd": 300,
      "usda_soil_texture_classification": "Loamy Sand; Sandy Loam; Coarse Sandy Loam; Fine Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (2-4 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 375,
      "min_bed_absorption_area_sqft": 500,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 300,
      "flow_used_for_sizing_gpd": 300,
      "usda_soil_texture_classification": "Loam; Fine Sandy Loam; Silt Loam; Very Fine Sand; Very Fine Sandy Loam; Loamy Fine Sand; Loamy Very Fine Sand; Sandy Clay Loam",
      "soil_texture_limitation_percolation_rate": "Moderately limited (5-10 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.65,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.35,
      "min_trench_absorption_area_sqft": 462,
      "min_bed_absorption_area_sqft": 858,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 300,
      "flow_used_for_sizing_gpd": 300,
      "usda_soil_texture_classification": "Clay Loam; Silty Clay Loam; Sandy Clay; Silty Clay; Silt",
      "soil_texture_limitation_percolation_rate": "Moderately limited (>15 but <=30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.35,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.2,
      "min_trench_absorption_area_sqft": 858,
      "min_bed_absorption_area_sqft": 1500,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 300,
      "flow_used_for_sizing_gpd": 300,
      "usda_soil_texture_classification": "Clay; Organic Soils; Hardpan; Bedrock",
      "soil_texture_limitation_percolation_rate": "Severely limited (>30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 300,
      "flow_used_for_sizing_gpd": 300,
      "usda_soil_texture_classification": "Coarse Sand with estimated wet season high water table within 48 inches of the bottom of the proposed drainfield; Gravel; Fractured Rock; Oolitic Limestone",
      "soil_texture_limitation_percolation_rate": "Severely limited (<1 min/inch and water table <4 ft below drainfield)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 400,
      "flow_used_for_sizing_gpd": 400,
      "usda_soil_texture_classification": "Sand; Coarse Sand not associated with a seasonal water table of less than 48 inches; Loamy Coarse Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (<2 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 500,
      "min_bed_absorption_area_sqft": 667,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 400,
      "flow_used_for_sizing_gpd": 400,
      "usda_soil_texture_classification": "Loamy Sand; Sandy Loam; Coarse Sandy Loam; Fine Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (2-4 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 500,
      "min_bed_absorption_area_sqft": 667,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 400,
      "flow_used_for_sizing_gpd": 400,
      "usda_soil_texture_classification": "Loam; Fine Sandy Loam; Silt Loam; Very Fine Sand; Very Fine Sandy Loam; Loamy Fine Sand; Loamy Very Fine Sand; Sandy Clay Loam",
      "soil_texture_limitation_percolation_rate": "Moderately limited (5-10 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.65,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.35,
      "min_trench_absorption_area_sqft": 616,
      "min_bed_absorption_area_sqft": 1143,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 400,
      "flow_used_for_sizing_gpd": 400,
      "usda_soil_texture_classification": "Clay Loam; Silty Clay Loam; Sandy Clay; Silty Clay; Silt",
      "soil_texture_limitation_percolation_rate": "Moderately limited (>15 but <=30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.35,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.2,
      "min_trench_absorption_area_sqft": 1143,
      "min_bed_absorption_area_sqft": 2000,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 400,
      "flow_used_for_sizing_gpd": 400,
      "usda_soil_texture_classification": "Clay; Organic Soils; Hardpan; Bedrock",
      "soil_texture_limitation_percolation_rate": "Severely limited (>30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 400,
      "flow_used_for_sizing_gpd": 400,
      "usda_soil_texture_classification": "Coarse Sand with estimated wet season high water table within 48 inches of the bottom of the proposed drainfield; Gravel; Fractured Rock; Oolitic Limestone",
      "soil_texture_limitation_percolation_rate": "Severely limited (<1 min/inch and water table <4 ft below drainfield)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 460,
      "flow_used_for_sizing_gpd": 460,
      "usda_soil_texture_classification": "Sand; Coarse Sand not associated with a seasonal water table of less than 48 inches; Loamy Coarse Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (<2 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 575,
      "min_bed_absorption_area_sqft": 767,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 460,
      "flow_used_for_sizing_gpd": 460,
      "usda_soil_texture_classification": "Loamy Sand; Sandy Loam; Coarse Sandy Loam; Fine Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (2-4 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 575,
      "min_bed_absorption_area_sqft": 767,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 460,
      "flow_used_for_sizing_gpd": 460,
      "usda_soil_texture_classification": "Loam; Fine Sandy Loam; Silt Loam; Very Fine Sand; Very Fine Sandy Loam; Loamy Fine Sand; Loamy Very Fine Sand; Sandy Clay Loam",
      "soil_texture_limitation_percolation_rate": "Moderately limited (5-10 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.65,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.35,
      "min_trench_absorption_area_sqft": 708,
      "min_bed_absorption_area_sqft": 1315,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 460,
      "flow_used_for_sizing_gpd": 460,
      "usda_soil_texture_classification": "Clay Loam; Silty Clay Loam; Sandy Clay; Silty Clay; Silt",
      "soil_texture_limitation_percolation_rate": "Moderately limited (>15 but <=30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.35,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.2,
      "min_trench_absorption_area_sqft": 1315,
      "min_bed_absorption_area_sqft": 2300,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 460,
      "flow_used_for_sizing_gpd": 460,
      "usda_soil_texture_classification": "Clay; Organic Soils; Hardpan; Bedrock",
      "soil_texture_limitation_percolation_rate": "Severely limited (>30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 460,
      "flow_used_for_sizing_gpd": 460,
      "usda_soil_texture_classification": "Coarse Sand with estimated wet season high water table within 48 inches of the bottom of the proposed drainfield; Gravel; Fractured Rock; Oolitic Limestone",
      "soil_texture_limitation_percolation_rate": "Severely limited (<1 min/inch and water table <4 ft below drainfield)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 520,
      "flow_used_for_sizing_gpd": 520,
      "usda_soil_texture_classification": "Sand; Coarse Sand not associated with a seasonal water table of less than 48 inches; Loamy Coarse Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (<2 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 650,
      "min_bed_absorption_area_sqft": 867,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 520,
      "flow_used_for_sizing_gpd": 520,
      "usda_soil_texture_classification": "Loamy Sand; Sandy Loam; Coarse Sandy Loam; Fine Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (2-4 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 650,
      "min_bed_absorption_area_sqft": 867,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 520,
      "flow_used_for_sizing_gpd": 520,
      "usda_soil_texture_classification": "Loam; Fine Sandy Loam; Silt Loam; Very Fine Sand; Very Fine Sandy Loam; Loamy Fine Sand; Loamy Very Fine Sand; Sandy Clay Loam",
      "soil_texture_limitation_percolation_rate": "Moderately limited (5-10 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.65,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.35,
      "min_trench_absorption_area_sqft": 800,
      "min_bed_absorption_area_sqft": 1486,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 520,
      "flow_used_for_sizing_gpd": 520,
      "usda_soil_texture_classification": "Clay Loam; Silty Clay Loam; Sandy Clay; Silty Clay; Silt",
      "soil_texture_limitation_percolation_rate": "Moderately limited (>15 but <=30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.35,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.2,
      "min_trench_absorption_area_sqft": 1486,
      "min_bed_absorption_area_sqft": 2600,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 520,
      "flow_used_for_sizing_gpd": 520,
      "usda_soil_texture_classification": "Clay; Organic Soils; Hardpan; Bedrock",
      "soil_texture_limitation_percolation_rate": "Severely limited (>30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 520,
      "flow_used_for_sizing_gpd": 520,
      "usda_soil_texture_classification": "Coarse Sand with estimated wet season high water table within 48 inches of the bottom of the proposed drainfield; Gravel; Fractured Rock; Oolitic Limestone",
      "soil_texture_limitation_percolation_rate": "Severely limited (<1 min/inch and water table <4 ft below drainfield)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 580,
      "flow_used_for_sizing_gpd": 580,
      "usda_soil_texture_classification": "Sand; Coarse Sand not associated with a seasonal water table of less than 48 inches; Loamy Coarse Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (<2 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 725,
      "min_bed_absorption_area_sqft": 967,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 580,
      "flow_used_for_sizing_gpd": 580,
      "usda_soil_texture_classification": "Loamy Sand; Sandy Loam; Coarse Sandy Loam; Fine Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (2-4 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 725,
      "min_bed_absorption_area_sqft": 967,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 580,
      "flow_used_for_sizing_gpd": 580,
      "usda_soil_texture_classification": "Loam; Fine Sandy Loam; Silt Loam; Very Fine Sand; Very Fine Sandy Loam; Loamy Fine Sand; Loamy Very Fine Sand; Sandy Clay Loam",
      "soil_texture_limitation_percolation_rate": "Moderately limited (5-10 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.65,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.35,
      "min_trench_absorption_area_sqft": 893,
      "min_bed_absorption_area_sqft": 1658,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 580,
      "flow_used_for_sizing_gpd": 580,
      "usda_soil_texture_classification": "Clay Loam; Silty Clay Loam; Sandy Clay; Silty Clay; Silt",
      "soil_texture_limitation_percolation_rate": "Moderately limited (>15 but <=30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.35,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.2,
      "min_trench_absorption_area_sqft": 1658,
      "min_bed_absorption_area_sqft": 2900,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 580,
      "flow_used_for_sizing_gpd": 580,
      "usda_soil_texture_classification": "Clay; Organic Soils; Hardpan; Bedrock",
      "soil_texture_limitation_percolation_rate": "Severely limited (>30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 580,
      "flow_used_for_sizing_gpd": 580,
      "usda_soil_texture_classification": "Coarse Sand with estimated wet season high water table within 48 inches of the bottom of the proposed drainfield; Gravel; Fractured Rock; Oolitic Limestone",
      "soil_texture_limitation_percolation_rate": "Severely limited (<1 min/inch and water table <4 ft below drainfield)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 640,
      "flow_used_for_sizing_gpd": 640,
      "usda_soil_texture_classification": "Sand; Coarse Sand not associated with a seasonal water table of less than 48 inches; Loamy Coarse Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (<2 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 800,
      "min_bed_absorption_area_sqft": 1067,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 640,
      "flow_used_for_sizing_gpd": 640,
      "usda_soil_texture_classification": "Loamy Sand; Sandy Loam; Coarse Sandy Loam; Fine Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (2-4 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 800,
      "min_bed_absorption_area_sqft": 1067,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 640,
      "flow_used_for_sizing_gpd": 640,
      "usda_soil_texture_classification": "Loam; Fine Sandy Loam; Silt Loam; Very Fine Sand; Very Fine Sandy Loam; Loamy Fine Sand; Loamy Very Fine Sand; Sandy Clay Loam",
      "soil_texture_limitation_percolation_rate": "Moderately limited (5-10 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.65,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.35,
      "min_trench_absorption_area_sqft": 985,
      "min_bed_absorption_area_sqft": 1829,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 640,
      "flow_used_for_sizing_gpd": 640,
      "usda_soil_texture_classification": "Clay Loam; Silty Clay Loam; Sandy Clay; Silty Clay; Silt",
      "soil_texture_limitation_percolation_rate": "Moderately limited (>15 but <=30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.35,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.2,
      "min_trench_absorption_area_sqft": 1829,
      "min_bed_absorption_area_sqft": 3200,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 640,
      "flow_used_for_sizing_gpd": 640,
      "usda_soil_texture_classification": "Clay; Organic Soils; Hardpan; Bedrock",
      "soil_texture_limitation_percolation_rate": "Severely limited (>30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 640,
      "flow_used_for_sizing_gpd": 640,
      "usda_soil_texture_classification": "Coarse Sand with estimated wet season high water table within 48 inches of the bottom of the proposed drainfield; Gravel; Fractured Rock; Oolitic Limestone",
      "soil_texture_limitation_percolation_rate": "Severely limited (<1 min/inch and water table <4 ft below drainfield)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 700,
      "flow_used_for_sizing_gpd": 700,
      "usda_soil_texture_classification": "Sand; Coarse Sand not associated with a seasonal water table of less than 48 inches; Loamy Coarse Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (<2 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 875,
      "min_bed_absorption_area_sqft": 1167,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 700,
      "flow_used_for_sizing_gpd": 700,
      "usda_soil_texture_classification": "Loamy Sand; Sandy Loam; Coarse Sandy Loam; Fine Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (2-4 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 875,
      "min_bed_absorption_area_sqft": 1167,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 700,
      "flow_used_for_sizing_gpd": 700,
      "usda_soil_texture_classification": "Loam; Fine Sandy Loam; Silt Loam; Very Fine Sand; Very Fine Sandy Loam; Loamy Fine Sand; Loamy Very Fine Sand; Sandy Clay Loam",
      "soil_texture_limitation_percolation_rate": "Moderately limited (5-10 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.65,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.35,
      "min_trench_absorption_area_sqft": 1077,
      "min_bed_absorption_area_sqft": 2000,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 700,
      "flow_used_for_sizing_gpd": 700,
      "usda_soil_texture_classification": "Clay Loam; Silty Clay Loam; Sandy Clay; Silty Clay; Silt",
      "soil_texture_limitation_percolation_rate": "Moderately limited (>15 but <=30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.35,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.2,
      "min_trench_absorption_area_sqft": 2000,
      "min_bed_absorption_area_sqft": 3500,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 700,
      "flow_used_for_sizing_gpd": 700,
      "usda_soil_texture_classification": "Clay; Organic Soils; Hardpan; Bedrock",
      "soil_texture_limitation_percolation_rate": "Severely limited (>30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 700,
      "flow_used_for_sizing_gpd": 700,
      "usda_soil_texture_classification": "Coarse Sand with estimated wet season high water table within 48 inches of the bottom of the proposed drainfield; Gravel; Fractured Rock; Oolitic Limestone",
      "soil_texture_limitation_percolation_rate": "Severely limited (<1 min/inch and water table <4 ft below drainfield)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 760,
      "flow_used_for_sizing_gpd": 760,
      "usda_soil_texture_classification": "Sand; Coarse Sand not associated with a seasonal water table of less than 48 inches; Loamy Coarse Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (<2 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 950,
      "min_bed_absorption_area_sqft": 1267,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 760,
      "flow_used_for_sizing_gpd": 760,
      "usda_soil_texture_classification": "Loamy Sand; Sandy Loam; Coarse Sandy Loam; Fine Sand",
      "soil_texture_limitation_percolation_rate": "Slightly limited (2-4 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.8,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.6,
      "min_trench_absorption_area_sqft": 950,
      "min_bed_absorption_area_sqft": 1267,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 760,
      "flow_used_for_sizing_gpd": 760,
      "usda_soil_texture_classification": "Loam; Fine Sandy Loam; Silt Loam; Very Fine Sand; Very Fine Sandy Loam; Loamy Fine Sand; Loamy Very Fine Sand; Sandy Clay Loam",
      "soil_texture_limitation_percolation_rate": "Moderately limited (5-10 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.65,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.35,
      "min_trench_absorption_area_sqft": 1170,
      "min_bed_absorption_area_sqft": 2172,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 760,
      "flow_used_for_sizing_gpd": 760,
      "usda_soil_texture_classification": "Clay Loam; Silty Clay Loam; Sandy Clay; Silty Clay; Silt",
      "soil_texture_limitation_percolation_rate": "Moderately limited (>15 but <=30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": 0.35,
      "max_loading_rate_bed_gal_per_sqft_per_day": 0.2,
      "min_trench_absorption_area_sqft": 2172,
      "min_bed_absorption_area_sqft": 3800,
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 760,
      "flow_used_for_sizing_gpd": 760,
      "usda_soil_texture_classification": "Clay; Organic Soils; Hardpan; Bedrock",
      "soil_texture_limitation_percolation_rate": "Severely limited (>30 min/inch)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    },
    {
      "design_sewage_flow_gpd": 760,
      "flow_used_for_sizing_gpd": 760,
      "usda_soil_texture_classification": "Coarse Sand with estimated wet season high water table within 48 inches of the bottom of the proposed drainfield; Gravel; Fractured Rock; Oolitic Limestone",
      "soil_texture_limitation_percolation_rate": "Severely limited (<1 min/inch and water table <4 ft below drainfield)",
      "max_loading_rate_trench_gal_per_sqft_per_day": "",
      "max_loading_rate_bed_gal_per_sqft_per_day": "",
      "min_trench_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "min_bed_absorption_area_sqft": "unsatisfactory for standard subsurface system",
      "rule_citation": "Fla. Admin. Code R. 62-6.008(5) and Table III",
      "source_url": "https://www.flrules.org/gateway/ruleno.asp?id=62-6.008",
      "verified_date": "2026-07-23"
    }
  ],
  "permitting_authority_by_county": [
    {
      "county": "Alachua",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Baker",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Bay",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Bradford",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Brevard",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Broward",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Calhoun",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Charlotte",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Citrus",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Clay",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Collier",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Columbia",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "DeSoto",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Dixie",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Duval",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Escambia",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Flagler",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Franklin",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Gadsden",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Gilchrist",
      "ostds_construction_permit_issued_by": "not listed in DEP's published county table",
      "listing_status_on_dep_table": "NOT LISTED - confirm directly with DEP",
      "how_to_apply_note": "This county does not appear in either column of DEP's Onsite Sewage FAQ - Permitting table as published on the page's stated Last Modified date. Confirm the permitting authority directly with DEP before relying on it.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Glades",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Gulf",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Hamilton",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Hardee",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Hendry",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Hernando",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Highlands",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Hillsborough",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Holmes",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Indian River",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Jackson",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Jefferson",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Lafayette",
      "ostds_construction_permit_issued_by": "not listed in DEP's published county table",
      "listing_status_on_dep_table": "NOT LISTED - confirm directly with DEP",
      "how_to_apply_note": "This county does not appear in either column of DEP's Onsite Sewage FAQ - Permitting table as published on the page's stated Last Modified date. Confirm the permitting authority directly with DEP before relying on it.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Lake",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Lee",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Leon",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Levy",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Liberty",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Madison",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Manatee",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Marion",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Martin",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Miami-Dade",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Monroe",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Nassau",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Okaloosa",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Okeechobee",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Orange",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Osceola",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Palm Beach",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Pasco",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Pinellas",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Polk",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Putnam",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Santa Rosa",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Sarasota",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Seminole",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "St. Johns",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "St. Lucie",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Sumter",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Suwannee",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Taylor",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Union",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Volusia",
      "ostds_construction_permit_issued_by": "Florida DOH county health department (Environmental Public Health)",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies to the local county health department, which also sets any county fees; DEP notes many counties have local ordinances that may exceed state requirements.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Wakulla",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Walton",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    },
    {
      "county": "Washington",
      "ostds_construction_permit_issued_by": "Florida DEP, Onsite Sewage Program",
      "listing_status_on_dep_table": "listed",
      "how_to_apply_note": "Applies via DEP online permit and service request portal (ostds.floridadep.gov) using Form DEP4015.",
      "source": "Florida DEP, Onsite Sewage FAQ - Permitting",
      "source_url": "https://floridadep.gov/water/onsite-sewage/content/onsite-sewage-faq-permitting",
      "source_page_last_modified": "2026-01-20",
      "verified_date": "2026-07-23"
    }
  ],
  "release_notes": [
    "Version 2026.2 updates the current effective date for Rule 62-6.013 to June 8, 2026.",
    "Corrects two exact 700-gpd drainfield calculations from 2,001 to 2,000 square feet.",
    "Renames the chamber fields as standalone minimums and adds the combined first-and-second capacity requirement as a separate field.",
    "Synchronizes the county permitting table with the Florida DEP page checked July 23, 2026."
  ]
}